PLC migration and modernization
Move legacy PLC programs onto current platforms
Altitude translates a program, or a single routine, onto another brand, controller or version, makes only the fixes the target needs to run it, and writes down every decision it made.
Studio 5000 Infeed_Conveyor.L5X · Ladder
TIA Portal Infeed.scl · SCL
TwinCAT 3 Infeed.TcPOU · Structured text
Translation report
Coverage 3 of 3 rungs translated
Decision Jam_Timer.DN is read as the IEC timer’s Q output
Address map 7 tags mapped, names kept
How it works
Step by step
- 1
Bring the source
An export from PLC-5, SLC 500, MicroLogix, Logix, STEP 7, TIA Portal or TwinCAT, or even a printout of the ladder, transcribed rung by rung first.
- 2
Translate
Translators carry SLC 500, MicroLogix and PLC-5 onto Logix, and move programs between Logix, TIA Portal and TwinCAT 3. Anything else is converted routine by routine.
- 3
Fix what the target needs
Each flag the translation raises is resolved in the target’s own instructions, or written out for the engineer at its place.
- 4
Review the report
Coverage, every decision and every flag, with an address map of where each tag and I/O point went.
What carries across
The translation keeps the program running the way it ran, in the target’s own instructions, and writes a report of every decision beside it.
- Task timing, with periodic tasks as tasks or cyclic interrupts of their own
- PID, PIDE and alarm instructions, ported from their documented behavior
- Motion, on PLCopen blocks
- I/O modules, matched to current modules of the same electrical kind
- Names, kept wherever the target allows them
Coverage
3 of 3 rungs
Flags left
None
Tags mapped
7
Decisions
- •Jam_Timer.DN is read as the IEC timer’s Q output.
- •The 3000 ms preset is written as T#3S.
- •MainTask’s period is kept as OB1’s cycle.
Address map
| Tag | Logix | TIA Portal | Address |
|---|---|---|---|
| Start_PB | Local:1:I.Data.0 | "Start_PB" | %I0.0 |
| Stop_PB | Local:1:I.Data.1 | "Stop_PB" | %I0.1 |
| Jam_Eye | Local:1:I.Data.4 | "Jam_Eye" | %I0.4 |
| Conveyor_Run | Local:2:O.Data.0 | "Conveyor_Run" | %Q0.0 |
| Jam_Timer | TIMER | "Jam_Timer" | TON_TIME |
From
- PLC-5
- SLC 500
- MicroLogix
- Older Logix controllers
- S5
- S7-300
- S7-400
- STEP 7 Classic
- TwinCAT 2
- Concept
- PL7
- Mitsubishi
- Printouts
To
- Studio 5000 Logix
- TIA Portal
- TwinCAT 3
Platforms
On the platforms you run
FAQ
Questions teams ask first
Does it change the original program?
Can it convert one routine instead of a whole controller?
Can it work from a printout?
Can it move a Logix project onto a newer controller?
Keep exploring
More ways teams use Altitude
See it on the work your team does every day
We'll walk through the workflows that matter most to your team, on the PLC, robot and HMI platforms you run, from review and troubleshooting to documents and migration.